    We offer a full service package to represent our international principals and support their local customers in Egypt: After-sales support including customs clearance, technical consultation, equipment installation, servicing and specialist sourcing of spare parts. ETU-LINK provides the following customer support: I. 24/7 Service: Providing 7x24-hour technical consultation and fault reporting services, ensuring customers receive a response within 24 hours of encountering any problems. The company was established by the late Eng. Onsi Sawiris over 30 years ago and is the agent for diverse, blue-chip Original. Address Line 2: Fourth Floor.


  • Energy Consumption Calculation of Distribution Box

    Energy Consumption Calculation of Distribution Box

    You don't need complex tools—just some basics: Circuit Load (Amps) = Appliance Wattage / Circuit Voltage But hold on—you can't max out the breaker! Electrical codes (like NEC) require breathing room. We follow the 80% rule : Safe Continuous Load = Circuit Breaker Rating × 0. 8Measuring system represents convenient method of monitoring the behavior and energy consumption of loads powered by the distribution box. Real-life example: For a 3-bedroom home, your total wattage demand might hover around 12,000W after applying realistic usage factors. Voltage Basics In most homes, you'll find: Here's where calculators. Design Distribution Box of one House and Calculation of Size of Main ELCB and branch Circuit MCB as following Load Detail. Power Supply is 430V (P-P), 230 (P-N), 50Hz. Compliance with IEC 61439 ensures that the distribution board meets global requirements for construction, protection, and performance. It helps organize, protect, and control electrical connections in residential, commercial, and industrial electrical systems.

    [PDF Version]
  • Optical Cable Reinforcing Core Pricing Calculation

    Optical Cable Reinforcing Core Pricing Calculation

    Basic — 1,000 ft single-mode run indoors with minimal termination: Cable $0. 00/ft, Permits $150, Accessories $100. 60/ft, Permits. Fiber optic cables are high-tech communications cables that carry information like bursts of light along extremely thin glass or plastic strands, providing high-speed, high-bandwidth connectivity with little loss of signal. This calculator allows you to plug in values for all variables that will impact your systems' performance. Compute the ratio between the diameter of your chosen cable and the diameter of the conduit you plan to use. It ensures that the received signal is strong enough for the equipment to process data without errors. For fiber cable materials only, expect $0.


  • Calculation Rules for Vertical Cable Tray Supports

    Calculation Rules for Vertical Cable Tray Supports

    Cable tray support quantity can be calculated using a simple formula: Support Quantity = Total Length ÷ Support Spacing + 1 20 ÷ 2 + 1 = 11 supports In a typical project, a 20-meter cable tray with 2-meter spacing requires 11 supports. Establishing partnerships with cus-tomers is a top priority for OBO, and OBO staff are available to support customers in all aspects of their pro-jects, including products, installation and planning advice. This is because we not only supply our customers with products and solutions, which. This publication is intended as a practical guide for the proper and safe* installation of cable ladder systems, cable tray systems, channel support systems and associated supports. Cable ladder systems and cable tray systems shall be manufactured in accordance with BS EN 61537, channel support. The National Electrical Code (NEC) is the ultimate authority for any cable tray installation. Specifically, NEC Article 392 governs the use, installation, and construction specifications for these systems.

    [PDF Version]
  • Design load of main distribution box

    Design load of main distribution box

    The following example will show you how to find the right size of single phase 230V AC consumer unit or garage unit and associated MCB/MCCB to handle the residential load.


  • How to ground the load end of the distribution box

    How to ground the load end of the distribution box

    Attach a ground wire from one of the threaded studs (A) at the bottom of the housing, to the mounting plate (B). This helps to reduce the potential difference that exists between conductive parts and the earth. Equipment Protection: Grounding protects substation. Power from factory ground must be installed by a qualified electrician. Each DISTRIBUTION BOX and controller must be grounded. 26 mm 2 (10 AWG) ground wire must be used, and in all other markets a 6 mm 2 must be used. Whether you're a seasoned pro or just starting out, this comprehensive guide will give you practical. The correct connection method of Distribution box grounding wire mainly includes the following steps: 1. This position is the connection point of the grounding wire in the. The grounding system provides a low-impedance path for fault current and limits the voltage rise on the normally non-current-carrying metallic components of the electrical distribution system.

    [PDF Version]
  • How to calculate the maximum load current of relay protection

    How to calculate the maximum load current of relay protection

    Motor protection relay settings are calculated from motor nameplate data, current transformer ratios, and system grounding method. Current Setting: The adjustment of the relay's pickup current by changing coil turns, expressed as a percentage of the CT's rated secondary current. Scenario: Step-by-Step Calculation: Final Overload Device Setting: Primary setting: 44 A (based on 125% rule). Adjusted setting: 49 A (if startup trips occur).


  • Calculation of the main circuit breaker for AC line cabinet

    Calculation of the main circuit breaker for AC line cabinet

    Main circuit breaker calculation is a step-by-step process that involves identifying total load, converting to current, applying demand factors, adding safety margins, and matching conductor size. Correct sizing prevents electrical hazards, ensures system reliability, and. Calculating the correct size of a main circuit breaker is one of the most important steps in electrical design. An undersized breaker trips frequently, while an oversized breaker poses serious fire risks. It is typically open-type, allowing easy replacement of contacts and parts, and can be equipped with various accessories. ACBs are commonly used as main power supply switches.


  • Fiber Optic Communication Sensitivity Calculation

    Fiber Optic Communication Sensitivity Calculation

    Sensitivity is the minimum average optical power in dBm to achieve a desired bit-error-rate (BER). Always compare back-to-back (transmitter directly to receiver) with maximum fiber length. Bit-Error Rate (BER) The calculation of BER for lightwave systems employing optical amplifiers follows the approach outlined in this tutorial - Optical. In optical communication systems, sensitivity is a measure of how weak an input signal can get before the bit-error ratio (BER) exceeds some specified number. For example, SONET specifies that the BER must be 10 -10 or better. Exceeding the BER value indicates signal degradation, rendering it unsuitable for data communication.


Fiber & Network Infrastructure Insights

Need Professional Fiber Optic & Network Solutions?

Contact us today for product inquiries, custom solutions, or technical support